2. Measurements Reported by SASBDB Reported Results
Metric
Method
Value
Uncertainty
Unit
dmax
P(r)
12.7
—
Å
i0
Guinier
93.3
0.201
—
i0
P(r)
89.2
—
—
mw
Experimental
50.7
—
kDa
rg
Guinier
2.88
0.022
Å
rg
P(r)
3.07
—
Å
These values are reported by SASBDB; SAXSdb did not recalculate them from the experimental curve.
▼
3. Source Fits and Models Source Fits & Models
This entry has no source fit record.
▶
4. Source File Index Source Files
Category
Path
Download status
Size
curve
sasbdb/entries/58/sasdb58/source/SASDB58.dat
downloaded
39488
full_entry_zip
sasbdb/entries/58/sasdb58/source/SASDB58.zip
downloaded
15236
pddf
sasbdb/entries/58/sasdb58/source/SASDB58.out
downloaded
5702
sascif
sasbdb/entries/58/sasdb58/source/SASDB58.sascif
not_available
—
summary
sasbdb/entries/58/sasdb58/source/summary.json
downloaded
7449
▶
5. Experiment Description and Publication Experiment & Publication
Original Experiment Description
Synchrotron SAXS data from solutions of Major viral transcription factor ICP4 (ICP4N dimer) in 20 mM HEPES, 150 mM NaCl, pH 7.4, were collected at the B21 beam line at the Diamond Light Source (Oxfordshire, UK) using a Pilatus 2M detector at a sample-detector distance of 3.9 m and at a wavelength of λ = 0.1 nm (I(s) vs s, where s = 4π sin θ/λ and 2θ is the scattering angle). Data were collected at 20°C using 17 successive 10 second frames at an undetermined sample concentration. The data were normalized to the intensity of the transmitted beam and radially averaged; the scattering of the solvent-blank was subtracted.
Related Publication
Title
The herpes viral transcription factor ICP4 forms a novel DNA recognition complex.
Authors
Tunnicliffe RB, Lockhart-Cairns MP, Levy C, Mould AP, Jowitt TA, Sito H, Baldock C, Sandri-Goldin RM, Golovanov AP
DOI / PMID
10.1093/nar/gkx419 / 28505309
▼
6. Complete Source Record Complete Source Record
The following content comes directly from the SASBDB entry. Missing values are shown as “—”; SAXSdb does not infer undeclared units.
Synchrotron SAXS data from solutions of Major viral transcription factor ICP4 (ICP4N dimer) in 20 mM HEPES, 150 mM NaCl, pH 7.4, were collected at the B21 beam line at the Diamond Light Source (Oxfordshire, UK) using a Pilatus 2M detector at a sample-detector distance of 3.9 m and at a wavelength of λ = 0.1 nm (I(s) vs s, where s = 4π sin θ/λ and 2θ is the scattering angle). Data were collected at 20°C using 17 successive 10 second frames at an undetermined sample concentration. The data were normalized to the intensity of the transmitted beam and radially averaged; the scattering of the solvent-blank was subtracted.