2. Measurements Reported by SASBDB Reported Results
Metric
Method
Value
Uncertainty
Unit
dmax
P(r)
13.9
—
Å
i0
Guinier
232.34
3.21
—
i0
P(r)
227.0
0.6
—
mw
Experimental
216.0
—
kDa
porod_volume
Porod
283.0
—
ų
rg
Guinier
4.5
0.06
Å
rg
P(r)
4.5
0.01
Å
These values are reported by SASBDB; SAXSdb did not recalculate them from the experimental curve.
▼
3. Source Fits and Models Source Fits & Models
This entry has no source fit record.
▶
4. Source File Index Source Files
Category
Path
Download status
Size
curve
sasbdb/entries/24/sasdc24/source/SASDC24.dat
downloaded
23085
full_entry_zip
sasbdb/entries/24/sasdc24/source/SASDC24.zip
downloaded
19679
pddf
sasbdb/entries/24/sasdc24/source/SASDC24.out
downloaded
47867
sascif
sasbdb/entries/24/sasdc24/source/SASDC24.sascif
downloaded
61860
summary
sasbdb/entries/24/sasdc24/source/summary.json
downloaded
8157
▶
5. Experiment Description and Publication Experiment & Publication
Original Experiment Description
Synchrotron SAXS data from solutions of Proline utilization A from Bradyrhizobium diazoefficiens (formerly Bradyrhizobium japonicum) R51E mutant in 50 mM Tris, 50 mM NaCl, 0.5 mM Tris(2-carboxyethyl)phosphine, and 5% (v/v) glycerol, pH 7.8 were collected on the 12.3.1 (SIBYLS) beam line at the Advanced Light Source (ALS; Berkeley, CA, USA) using a Pilatus3 X 2M detector (I(s) vs s, where s = 4πsinθ/λ and 2θ is the scattering angle). One solute concentration of 4.7 mg/ml was measured. The data were normalized to the intensity of the transmitted beam and radially averaged. The radially averaged scattering of the solvent-blank was subtracted. X-ray wavelength, unknown; Exposure time, unknown; Sample-To-Detector distance, unknown.
Related Publication
Title
Biophysical investigation of type A PutAs reveals a conserved core oligomeric structure.
Authors
Korasick DA, Singh H, Pemberton TA, Luo M, Dhatwalia R, Tanner JJ
DOI / PMID
10.1111/febs.14165 / 28710792
▼
6. Complete Source Record Complete Source Record
The following content comes directly from the SASBDB entry. Missing values are shown as “—”; SAXSdb does not infer undeclared units.
Synchrotron SAXS data from solutions of Proline utilization A from Bradyrhizobium diazoefficiens (formerly Bradyrhizobium japonicum) R51E mutant in 50 mM Tris, 50 mM NaCl, 0.5 mM Tris(2-carboxyethyl)phosphine, and 5% (v/v) glycerol, pH 7.8 were collected on the 12.3.1 (SIBYLS) beam line at the Advanced Light Source (ALS; Berkeley, CA, USA) using a Pilatus3 X 2M detector (I(s) vs s, where s = 4πsinθ/λ and 2θ is the scattering angle). One solute concentration of 4.7 mg/ml was measured. The data were normalized to the intensity of the transmitted beam and radially averaged. The radially averaged scattering of the solvent-blank was subtracted. X-ray wavelength, unknown; Exposure time, unknown; Sample-To-Detector distance, unknown.