SAXS data from solutions of the basic domain of telomeric repeat-binding factor 2 (TRF2) in 50 mM sodium phosphate, 50 mM NaCl, pH 7, were collected using a Rigaku BioSAXS-1000 instrument at CEITEC (Brno, Czech Republic) equipped with a Pilatus 100K detector at a sample-detector distance of 0.5 m (I(s) vs s, where = 4π sin θ/λ; 2θ is the scattering angle and λ = 0.154 nm). Six successive 3600 second frames were collected at a sample temperature of 4°C using a solute concentration of 1.2 mg/ml. The data were normalized to the intensity of the transmitted beam and radially averaged and the corresponding scattering from the solvent-blank was subtracted to produced the scattering profile displayed in this entry.
相关论文
标题
Basic domain of telomere guardian TRF2 reduces D-loop unwinding whereas Rap1 restores it.
CEITEC - Central European Institute of Technology, Masaryk University
experiment.contributor[0].affiliation[0].webpage
https://www.ceitec.eu/
experiment.contributor[0].contributor_name
Tomas
experiment.contributor[0].contributor_surname
Klumpler
experiment.contributor[0].orcid
null
experiment.concentration_method
null
experiment.concentration_unit
null
experiment.date
2015-03-05
experiment.storage_temperature
4.0
experiment.cell_temperature
4.0
experiment.exposure_time
3600.0
experiment.number_of_frames
6
experiment.wavelength
1.54
experiment.sample_detector_distance
0.48
experiment.concentration_min
null
experiment.concentration_max
1.2
experiment.sample_volume
null
experiment.flow_rate
null
experiment.s_min
0.109
experiment.s_max
6.503
experiment.total_exposure_time
null
experiment.seccolumn
null
fits
[]
estimated_volume_method
null
pddf_software
ATSAS GNOM
pddf_software_version
primus/qt r8972
i0_calibration_standard
null
description
null
experiment_description
SAXS data from solutions of the basic domain of telomeric repeat-binding factor 2 (TRF2) in 50 mM sodium phosphate, 50 mM NaCl, pH 7, were collected using a Rigaku BioSAXS-1000 instrument at CEITEC (Brno, Czech Republic) equipped with a Pilatus 100K detector at a sample-detector distance of 0.5 m (I(s) vs s, where = 4π sin θ/λ; 2θ is the scattering angle and λ = 0.154 nm). Six successive 3600 second frames were collected at a sample temperature of 4°C using a solute concentration of 1.2 mg/ml. The data were normalized to the intensity of the transmitted beam and radially averaged and the corresponding scattering from the solvent-blank was subtracted to produced the scattering profile displayed in this entry.