2. Measurements Reported by SASBDB Reported Results
Metric
Method
Value
Uncertainty
Unit
dmax
P(r)
10.0
—
Å
i0
Guinier
0.08048
5e-05
—
i0
P(r)
0.07925
4e-05
—
mw
Experimental
125.0
—
kDa
mw
Porod
116.0
—
kDa
porod_volume
Porod
197.18
—
ų
rg
Guinier
3.45
0.003
Å
rg
P(r)
3.363
0.002
Å
These values are reported by SASBDB; SAXSdb did not recalculate them from the experimental curve.
▼
3. Source Fits and Models Source Fits & Models
This entry has no source fit record.
▶
4. Source File Index Source Files
Category
Path
Download status
Size
curve
sasbdb/entries/c2/sasdcc2/source/SASDCC2.dat
downloaded
55870
full_entry_zip
sasbdb/entries/c2/sasdcc2/source/SASDCC2.zip
downloaded
26126
pddf
sasbdb/entries/c2/sasdcc2/source/SASDCC2.out
downloaded
42541
sascif
sasbdb/entries/c2/sasdcc2/source/SASDCC2.sascif
downloaded
94225
summary
sasbdb/entries/c2/sasdcc2/source/summary.json
downloaded
7969
▶
5. Experiment Description and Publication Experiment & Publication
Original Experiment Description
Synchrotron SAXS data from solutions of Rab family protein CtRoc-COR GDP in 20 mM HEPES 150 mM NaCl 5 mM MgCl2 5% Glycerol 1 mM DTT 200µ M GDP, pH 7.5 were collected on the SWING camera on the storage ring SOLEIL (Saint-Aubin, France) using a CCD AVIEX detector at a wavelength of λ = 0.103 nm (I(s) vs s, where s = 4πsin θ/λ and 2θ is the scattering angle). Inline SEC-SAXS was employed at 25°C (50 µl injection volume of an 8 mg/ml protein solution on a Bio SEC-3 HPLC column (Agilent, 3 µm 300 Å)). 29 successive 0.750 second frames were collected through the elution peak. The data were normalized to the intensity of the transmitted beam and radially averaged; the scattering of the solvent-blank was subtracted and the different curves were scaled and averaged to produce the final SAXS data displayed in this entry.
Related Publication
Title
A homologue of the Parkinson's disease-associated protein LRRK2 undergoes a monomer-dimer transition during GTP turnover.
Authors
Deyaert E, Wauters L, Guaitoli G, Konijnenberg A, Leemans M, Terheyden S, Petrovic A, Gallardo R, Nederveen-Schippers LM, Athanasopoulos PS, Pots H, Van Haastert PJM, Sobott F, Gloeckner CJ, Efremov R, Kortholt A, Versées W
DOI / PMID
10.1038/s41467-017-01103-4 / 29044096
▼
6. Complete Source Record Complete Source Record
The following content comes directly from the SASBDB entry. Missing values are shown as “—”; SAXSdb does not infer undeclared units.
Every source field is expanded here, including empty values, list members and fields already shown above.
summary.json:134 field values
Field path
Raw value
code
SASDCC2
status
Published
type_of_curve
Other
angular_unit
1/A
project.title
A homologue of the Parkinson's disease-associated protein LRRK2 undergoes a monomer-dimer transition during GTP turnover.
project.publication.title
A homologue of the Parkinson's disease-associated protein LRRK2 undergoes a monomer-dimer transition during GTP turnover.
project.publication.author_list
Deyaert E, Wauters L, Guaitoli G, Konijnenberg A, Leemans M, Terheyden S, Petrovic A, Gallardo R, Nederveen-Schippers LM, Athanasopoulos PS, Pots H, Van Haastert PJM, Sobott F, Gloeckner CJ, Efremov R, Kortholt A, Versées W
Synchrotron SAXS data from solutions of Rab family protein CtRoc-COR GDP in 20 mM HEPES 150 mM NaCl 5 mM MgCl2 5% Glycerol 1 mM DTT 200µ M GDP, pH 7.5 were collected on the SWING camera on the storage ring SOLEIL (Saint-Aubin, France) using a CCD AVIEX detector at a wavelength of λ = 0.103 nm (I(s) vs s, where s = 4πsin θ/λ and 2θ is the scattering angle). Inline SEC-SAXS was employed at 25°C (50 µl injection volume of an 8 mg/ml protein solution on a Bio SEC-3 HPLC column (Agilent, 3 µm 300 Å)). 29 successive 0.750 second frames were collected through the elution peak. The data were normalized to the intensity of the transmitted beam and radially averaged; the scattering of the solvent-blank was subtracted and the different curves were scaled and averaged to produce the final SAXS data displayed in this entry.