2. Measurements Reported by SASBDB Reported Results
Metric
Method
Value
Uncertainty
Unit
dmax
P(r)
12.2
—
Å
i0
Guinier
0.05142
6.1e-05
1/cm
i0
P(r)
0.05143
2e-05
1/cm
mw
Experimental
66.7
—
kDa
mw
Porod
67.0
—
kDa
porod_volume
Porod
95.0
—
ų
rg
Guinier
3.46
0.08
Å
rg
P(r)
3.52
0.002
Å
These values are reported by SASBDB; SAXSdb did not recalculate them from the experimental curve.
▼
3. Source Fits and Models Source Fits & Models
This entry has no source fit record.
▶
4. Source File Index Source Files
Category
Path
Download status
Size
curve
sasbdb/entries/n8/sasdcn8/source/SASDCN8.dat
downloaded
138819
full_entry_zip
sasbdb/entries/n8/sasdcn8/source/SASDCN8.zip
downloaded
32650
pddf
sasbdb/entries/n8/sasdcn8/source/SASDCN8.out
downloaded
32109
sascif
sasbdb/entries/n8/sasdcn8/source/SASDCN8.sascif
downloaded
74816
summary
sasbdb/entries/n8/sasdcn8/source/summary.json
downloaded
6820
▶
5. Experiment Description and Publication Experiment & Publication
Original Experiment Description
Synchrotron SAXS data from solutions of SAXS data of Legionella pneumophila phosphocholine hydrolase (19-570) in 300 mM NaCl, 2 mM 2-mercaptoethanol and 30 mM Tris-HCl, pH 7.5 were collected on the SWING beam line at the SOLEIL storage ring (Saint-Aubin, France) using a CCD AVIEX detector at a sample-detector distance of 1.2 m and at a wavelength of λ = 0.102 nm (I(s) vs s, where s = 4πsinθ/λ and 2θ is the scattering angle). Solute concentrations ranging between 4 and 6 mg/ml were measured at 15°C for a total exposure time of 1.5 s. The data were normalized to the intensity of the transmitted beam and radially averaged; the scattering of the solvent-blank was subtracted and the data were scaled for protein concentration.
▼
6. Complete Source Record Complete Source Record
The following content comes directly from the SASBDB entry. Missing values are shown as “—”; SAXSdb does not infer undeclared units.
Synchrotron SAXS data from solutions of SAXS data of Legionella pneumophila phosphocholine hydrolase (19-570) in 300 mM NaCl, 2 mM 2-mercaptoethanol and 30 mM Tris-HCl, pH 7.5 were collected on the SWING beam line at the SOLEIL storage ring (Saint-Aubin, France) using a CCD AVIEX detector at a sample-detector distance of 1.2 m and at a wavelength of λ = 0.102 nm (I(s) vs s, where s = 4πsinθ/λ and 2θ is the scattering angle). Solute concentrations ranging between 4 and 6 mg/ml were measured at 15°C for a total exposure time of 1.5 s. The data were normalized to the intensity of the transmitted beam and radially averaged; the scattering of the solvent-blank was subtracted and the data were scaled for protein concentration.