Only one concentration was measured. There might be some repulsive interactions as the guinier region is not linear and the Rg and volume are smaller than expected.
Synchrotron SAXS data from solutions of glucose isomerase in 100 mM HEPES, 1 mM MgCl2, pH 7 were collected at the EMBL-P12 beam line at the PETRA III storage ring (Hamburg, Germany) using an Eiger 4M detector at a sample-detector distance of 1.6 m and at a wavelength of λ = 0.124 nm (I(s) vs s, where s = 4πsinθ/λ and 2θ is the scattering angle). One solute concentration of 4.07 mg/ml was measured at 20°C. A single 1.3 millisecond frame was collected. The data were normalized to the intensity of the transmitted beam and radially averaged; the scattering of the solvent-blank was subtracted and the data were scaled to the protein concentration.
European Molecular Biology Laboratory (EMBL) - Hamburg outstation
experiment.contributor[0].affiliation[0].webpage
http://www.embl-hamburg.de/index.php
experiment.contributor[0].contributor_name
Clement
experiment.contributor[0].contributor_surname
Blanchet
experiment.contributor[0].orcid
null
experiment.concentration_method
null
experiment.concentration_unit
null
experiment.date
2016-12-21
experiment.storage_temperature
20.0
experiment.cell_temperature
20.0
experiment.exposure_time
0.001
experiment.number_of_frames
1
experiment.wavelength
0.124
experiment.sample_detector_distance
1.6
experiment.concentration_min
null
experiment.concentration_max
4.07
experiment.sample_volume
null
experiment.flow_rate
null
experiment.s_min
0.087
experiment.s_max
5.504
experiment.total_exposure_time
null
experiment.seccolumn
null
fits
[]
estimated_volume_method
null
pddf_software
null
pddf_software_version
null
i0_calibration_standard
null
description
Only one concentration was measured. There might be some repulsive interactions as the guinier region is not linear and the Rg and volume are smaller than expected.
experiment_description
Synchrotron SAXS data from solutions of glucose isomerase in 100 mM HEPES, 1 mM MgCl2, pH 7 were collected at the EMBL-P12 beam line at the PETRA III storage ring (Hamburg, Germany) using an Eiger 4M detector at a sample-detector distance of 1.6 m and at a wavelength of λ = 0.124 nm (I(s) vs s, where s = 4πsinθ/λ and 2θ is the scattering angle). One solute concentration of 4.07 mg/ml was measured at 20°C. A single 1.3 millisecond frame was collected. The data were normalized to the intensity of the transmitted beam and radially averaged; the scattering of the solvent-blank was subtracted and the data were scaled to the protein concentration.