The data displayed in this entry represents the averaged 1D-SAXS profile obtained from 100 individual SAXS data frames. Included in the full entry zip-archive are each of the individual subtracted SAXS profiles as well as each individual sample and buffer frame (100 in total).
▼
1. 样品、组分与实验条件 Sample & Experiment
样品 1 · Bovine serum albumin mixture: averaged and individual data frames (subtracted and unsubtracted test sets)
Synchrotron SAXS data from a solution of bovine serum albumin (mixture) in 50 mM HEPES, pH 7.5, were collected on the EMBL-P12 beam line at the PETRA III storage ring (DESY, Hamburg, Germany) using a Pilatus 2M detector at a sample-detector distance of 3.1 m and at a wavelength of λ = 0.124 nm (l(s) vs s, where s = 4πsinθ/λ, and 2θ is the scattering angle). One solute concentration of 2.25 mg/ml was measured at 10°C. 100 successive 0.050 second frames were collected. The data were normalized to the intensity of the transmitted beam and radially averaged; the scattering of the solvent-blank was subtracted.
相关论文
标题
Machine Learning Methods for X-Ray Scattering Data Analysis from Biomacromolecular Solutions.
European Molecular Biology Laboratory (EMBL) - Hamburg outstation
experiment.contributor[0].affiliation[0].webpage
http://www.embl-hamburg.de/index.php
experiment.contributor[0].contributor_name
Cy M
experiment.contributor[0].contributor_surname
Jeffries
experiment.contributor[0].orcid
null
experiment.concentration_method
null
experiment.concentration_unit
null
experiment.date
2016-09-25
experiment.storage_temperature
10.0
experiment.cell_temperature
10.0
experiment.exposure_time
0.05
experiment.number_of_frames
100
experiment.wavelength
0.124
experiment.sample_detector_distance
3.1
experiment.concentration_min
null
experiment.concentration_max
2.25
experiment.sample_volume
null
experiment.flow_rate
null
experiment.s_min
0.013
experiment.s_max
3.79
experiment.total_exposure_time
null
experiment.seccolumn
null
fits
[]
estimated_volume_method
null
pddf_software
ATSAS GNOM
pddf_software_version
5.0
i0_calibration_standard
null
description
The data displayed in this entry represents the averaged 1D-SAXS profile obtained from 100 individual SAXS data frames. Included in the full entry zip-archive are each of the individual subtracted SAXS profiles as well as each individual sample and buffer frame (100 in total).
experiment_description
Synchrotron SAXS data from a solution of bovine serum albumin (mixture) in 50 mM HEPES, pH 7.5, were collected on the EMBL-P12 beam line at the PETRA III storage ring (DESY, Hamburg, Germany) using a Pilatus 2M detector at a sample-detector distance of 3.1 m and at a wavelength of λ = 0.124 nm (l(s) vs s, where s = 4πsinθ/λ, and 2θ is the scattering angle). One solute concentration of 2.25 mg/ml was measured at 10°C. 100 successive 0.050 second frames were collected. The data were normalized to the intensity of the transmitted beam and radially averaged; the scattering of the solvent-blank was subtracted.