Synchrotron SAXS data from solutions of mothers against decapentaplegic homolog 8_9 (Smad8_9 MH1) in 20 mM Tris 150 mM NaCl, pH 7.2 were collected on the BM29 beam line at the ESRF (Grenoble, France) using a Pilatus 1M detector at a sample-to-detector distance of 2.87 m and an X-ray wavelength, λ, of 0.09919 nm (l(s) vs s, where s = 4πsinθ/λ, and 2θ is the scattering angle). One solute concentration of 7.69 mg/ml was measured at 10°C. 10 successive 1 s frames were collected. The data were normalized to the intensity of the transmitted beam and radially averaged; the scattering of the solvent-blank was subtracted. The data is recorded from a sample in monomer-dimer equilibrium.
相关论文
标题
Unveiling the dimer/monomer propensities of Smad MH1-DNA complexes
作者
Ruiz L, Kaczmarska Z, Gomes T, Aragón E, Torner C, Freier R, Bagiński B, Martin-Malpartida P, de Martin Garrido N, Márquez J, Cordeiro T, Pluta R, Macias M
Institute for Research in Biomedicine in Barcelona (IRB)
experiment.contributor[0].affiliation[0].webpage
https://www.irbbarcelona.org
experiment.contributor[0].contributor_name
Tiago
experiment.contributor[0].contributor_surname
Lopes
experiment.contributor[0].orcid
experiment.concentration_method
null
experiment.concentration_unit
null
experiment.date
2018-03-01
experiment.storage_temperature
10.0
experiment.cell_temperature
10.0
experiment.exposure_time
1.0
experiment.number_of_frames
10
experiment.wavelength
0.09919
experiment.sample_detector_distance
2.87
experiment.concentration_min
null
experiment.concentration_max
7.69
experiment.sample_volume
null
experiment.flow_rate
null
experiment.s_min
0.295
experiment.s_max
4.928
experiment.total_exposure_time
null
experiment.seccolumn
null
fits
[]
estimated_volume_method
null
pddf_software
ScÅtter
pddf_software_version
null
i0_calibration_standard
null
description
null
experiment_description
Synchrotron SAXS data from solutions of mothers against decapentaplegic homolog 8_9 (Smad8_9 MH1) in 20 mM Tris 150 mM NaCl, pH 7.2 were collected on the BM29 beam line at the ESRF (Grenoble, France) using a Pilatus 1M detector at a sample-to-detector distance of 2.87 m and an X-ray wavelength, λ, of 0.09919 nm (l(s) vs s, where s = 4πsinθ/λ, and 2θ is the scattering angle). One solute concentration of 7.69 mg/ml was measured at 10°C. 10 successive 1 s frames were collected. The data were normalized to the intensity of the transmitted beam and radially averaged; the scattering of the solvent-blank was subtracted. The data is recorded from a sample in monomer-dimer equilibrium.