2. Measurements Reported by SASBDB Reported Results
Metric
Method
Value
Uncertainty
Unit
dmax
P(r)
15.1
—
nm
i0
Guinier
26.33
0.03
arbitrary
i0
P(r)
26.81
—
arbitrary
mw
Experimental
26.33
—
kDa
mw
Porod
33.0
—
kDa
porod_volume
Porod
52.0
—
nm³
rg
Guinier
3.66
0.07
nm
rg
P(r)
3.926
—
nm
These values are reported by SASBDB; SAXSdb did not recalculate them from the experimental curve.
▼
3. Source Fits and Models Source Fits & Models
This entry has no source fit record.
▶
4. Source File Index Source Files
Category
Path
Download status
Size
curve
sasbdb/entries/28/sasdf28/source/SASDF28.dat
downloaded
97756
full_entry_zip
sasbdb/entries/28/sasdf28/source/SASDF28.zip
downloaded
43319
pddf
sasbdb/entries/28/sasdf28/source/SASDF28.out
downloaded
70908
sascif
sasbdb/entries/28/sasdf28/source/SASDF28.sascif
downloaded
168082
summary
sasbdb/entries/28/sasdf28/source/summary.json
downloaded
6799
▶
5. Experiment Description and Publication Experiment & Publication
Original Experiment Description
Synchrotron SAXS data from solutions of myotilin Ig1Ig2 (220-452) in 20 mM Na+-HEPES, 150 mM, NaCl, 5 % v/v glycerol, 1 mM DTT, pH 7.4 were collected on the BM29 beam line at the ESRF (Grenoble, France) using a Pilatus 1M detector at a sample-detector distance of 2.9 m and at a wavelength of λ = 0.099 nm (I(s) vs s, where s = 4πsinθ/λ, and 2θ is the scattering angle). One solute concentration of 21.00 mg/ml was measured at 20°C. 15 successive 1 second frames were collected. The data were normalized to the intensity of the transmitted beam and radially averaged; the scattering of the solvent-blank was subtracted.
Related Publication
Title
Molecular basis of F-actin regulation and sarcomere assembly via myotilin
Authors
Kostan J, Pavšič M, Puž V, Schwarz T, Drepper F, Molt S, Graewert M, Schreiner C, Sajko S, van der Ven P, Onipe A, Svergun D, Warscheid B, Konrat R, Fürst D, Lenarčič B, Djinović-Carugo K, Machesky L
DOI / PMID
10.1371/journal.pbio.3001148 / —
▼
6. Complete Source Record Complete Source Record
The following content comes directly from the SASBDB entry. Missing values are shown as “—”; SAXSdb does not infer undeclared units.
Every source field is expanded here, including empty values, list members and fields already shown above.
summary.json:134 field values
Field path
Raw value
code
SASDF28
status
Published
type_of_curve
Single concentration
angular_unit
1/nm
project.title
Molecular basis of F-actin regulation and sarcomere assembly via myotilin
project.publication.title
Molecular basis of F-actin regulation and sarcomere assembly via myotilin
project.publication.author_list
Kostan J, Pavšič M, Puž V, Schwarz T, Drepper F, Molt S, Graewert M, Schreiner C, Sajko S, van der Ven P, Onipe A, Svergun D, Warscheid B, Konrat R, Fürst D, Lenarčič B, Djinović-Carugo K, Machesky L
European Molecular Biology Laboratory (EMBL) - Hamburg outstation
experiment.contributor[0].affiliation[0].webpage
http://www.embl-hamburg.de/index.php
experiment.contributor[0].contributor_name
Melissa
experiment.contributor[0].contributor_surname
Graewert
experiment.contributor[0].orcid
null
experiment.concentration_method
null
experiment.concentration_unit
null
experiment.date
2010-11-16
experiment.storage_temperature
null
experiment.cell_temperature
20.0
experiment.exposure_time
1.0
experiment.number_of_frames
15
experiment.wavelength
0.099
experiment.sample_detector_distance
2.867
experiment.concentration_min
null
experiment.concentration_max
21.0
experiment.sample_volume
null
experiment.flow_rate
null
experiment.s_min
0.059
experiment.s_max
6.016
experiment.total_exposure_time
null
experiment.seccolumn
null
fits
[]
estimated_volume_method
null
pddf_software
ATSAS GNOM
pddf_software_version
5.0
i0_calibration_standard
null
description
null
experiment_description
Synchrotron SAXS data from solutions of myotilin Ig1Ig2 (220-452) in 20 mM Na+-HEPES, 150 mM, NaCl, 5 % v/v glycerol, 1 mM DTT, pH 7.4 were collected on the BM29 beam line at the ESRF (Grenoble, France) using a Pilatus 1M detector at a sample-detector distance of 2.9 m and at a wavelength of λ = 0.099 nm (I(s) vs s, where s = 4πsinθ/λ, and 2θ is the scattering angle). One solute concentration of 21.00 mg/ml was measured at 20°C. 15 successive 1 second frames were collected. The data were normalized to the intensity of the transmitted beam and radially averaged; the scattering of the solvent-blank was subtracted.