2. Measurements Reported by SASBDB Reported Results
Metric
Method
Value
Uncertainty
Unit
dmax
P(r)
7.74
—
Å
i0
Guinier
0.001574
1.2e-05
arbitrary
i0
P(r)
0.001541
0.0001
arbitrary
mw
Experimental
33.825
—
kDa
mw
Porod
29.0
—
kDa
porod_volume
Porod
43.0
—
ų
rg
Guinier
2.562
0.033
Å
rg
P(r)
2.484
0.02
Å
These values are reported by SASBDB; SAXSdb did not recalculate them from the experimental curve.
▼
3. Source Fits and Models Source Fits & Models
This entry has no source fit record.
▶
4. Source File Index Source Files
Category
Path
Download status
Size
curve
sasbdb/entries/n4/sasdfn4/source/SASDFN4.dat
downloaded
69902
full_entry_zip
sasbdb/entries/n4/sasdfn4/source/SASDFN4.zip
downloaded
38033
pddf
sasbdb/entries/n4/sasdfn4/source/SASDFN4.out
downloaded
64132
sascif
sasbdb/entries/n4/sasdfn4/source/SASDFN4.sascif
downloaded
136149
summary
sasbdb/entries/n4/sasdfn4/source/summary.json
downloaded
6849
▶
5. Experiment Description and Publication Experiment & Publication
Original Experiment Description
Synchrotron SAXS data from solutions of the domain-stapled mutant of matrix metalloproteinase-1 (MMP-1 S243C, S318C) in 50 mM Tris-HCl, 150 mM NaCl, 10 mM CaCl2, pH 7.4 were collected using size-exclusion chromatography SAXS (SEC-SAXS) on the B21 beam line at the Diamond Light Source (Oxfordshire, UK) using a Pilatus 2M detector at a sample-detector distance of 3.9 m and at a wavelength of λ = 0.1 nm (I(s) vs s, where s = 4πsinθ/λ, and 2θ is the scattering angle). SEC-SAXS was performed at 25 °C using the following parameters: Shodex Kw-403 analytical SEC column; Flow rate: 0.2 mL/min; Sample injection concentration: 8 mg/mL; Injection volume: 45 μL. The data were collected through the SEC peak of the sample as a series of 29 x 3 second exposures. Each unsubtracted data frame was normalised to the intensity of the transmitted beam and radially averaged and the scattering of an appropriate solvent-blank was subtracted. The resulting subtracted frames were scaled and averaged to generate the final SAXS profile displayed in this entry.
▼
6. Complete Source Record Complete Source Record
The following content comes directly from the SASBDB entry. Missing values are shown as “—”; SAXSdb does not infer undeclared units.
Synchrotron SAXS data from solutions of the domain-stapled mutant of matrix metalloproteinase-1 (MMP-1 S243C, S318C) in 50 mM Tris-HCl, 150 mM NaCl, 10 mM CaCl2, pH 7.4 were collected using size-exclusion chromatography SAXS (SEC-SAXS) on the B21 beam line at the Diamond Light Source (Oxfordshire, UK) using a Pilatus 2M detector at a sample-detector distance of 3.9 m and at a wavelength of λ = 0.1 nm (I(s) vs s, where s = 4πsinθ/λ, and 2θ is the scattering angle). SEC-SAXS was performed at 25 °C using the following parameters: Shodex Kw-403 analytical SEC column; Flow rate: 0.2 mL/min; Sample injection concentration: 8 mg/mL; Injection volume: 45 μL. The data were collected through the SEC peak of the sample as a series of 29 x 3 second exposures. Each unsubtracted data frame was normalised to the intensity of the transmitted beam and radially averaged and the scattering of an appropriate solvent-blank was subtracted. The resulting subtracted frames were scaled and averaged to generate the final SAXS profile displayed in this entry.