Data type: SASBDB experimental dataStatus: PublishedCurve type: Single concentrationLast updated: 2025-03-17T16:06:56.273192+01:00
Minimum q reliable is ~0.15 nm-1, approximated by a standard sample (lysozyme protein) scattering. DrugBank ID: DB11914: https://go.drugbank.com/drugs/DB11914
▼
1. Samples, Components and Experimental Conditions Sample & Experiment
Sample 1 · Immunoglobulin G4 (pH 7)
Concentration
— – 1.2
Buffer / pH
10 mM sodium phosphate / 7.0
Experimental temperature
25.0
Facility / beamline
Photon Factory (PF), High Energy Accelerator Research Organization (KEK) / BL-10C
2. Measurements Reported by SASBDB Reported Results
Metric
Method
Value
Uncertainty
Unit
dmax
P(r)
15.61
—
Å
i0
Guinier
0.106735
—
1/cm
i0
P(r)
0.1071
—
1/cm
mw
Experimental
146.0
—
kDa
mw
Guinier I(0)
146.0
2.0
kDa
mw
Porod
132.0
—
kDa
porod_volume
Porod
211.0
—
ų
rg
Guinier
4.829
0.708
Å
rg
P(r)
4.88
—
Å
These values are reported by SASBDB; SAXSdb did not recalculate them from the experimental curve.
▼
3. Source Fits and Models Source Fits & Models
This entry has no source fit record.
▶
4. Source File Index Source Files
Category
Path
Download status
Size
curve
sasbdb/entries/64/sasdw64/source/SASDW64.dat
downloaded
12102
full_entry_zip
sasbdb/entries/64/sasdw64/source/SASDW64.zip
downloaded
13992
pddf
sasbdb/entries/64/sasdw64/source/SASDW64.out
downloaded
31669
sascif
sasbdb/entries/64/sasdw64/source/SASDW64.sascif
not_available
—
summary
sasbdb/entries/64/sasdw64/source/summary.json
downloaded
7611
▶
5. Experiment Description and Publication Experiment & Publication
Original Experiment Description
Synchrotron SAXS data from solutions of Immunoglobulin G4 in 10 mM sodium phosphate, pH 7 were collected on the BL-10C beam line at the Photon Factory High Energy Accelerator Research Organization (KEK; Tsukuba, Japan) using a Pilatus3 2M detector at a sample-detector distance of 1 m and at a wavelength of λ = 0.15 nm (I(s) vs s, where s = 4πsinθ/λ, and 2θ is the scattering angle). One solute concentration of 1.20 mg/ml was measured at 25°C. Five successive 2 second frames were collected. The data were normalized to the intensity of the transmitted beam and radially averaged; the scattering of the solvent-blank was subtracted.
Related Publication
Title
<scp>IgG4</scp>
and <scp>IgG1</scp>
undergo common acid‐induced compaction into an alternatively folded state
Authors
Imamura H, Honda S
DOI / PMID
10.1002/1873-3468.70031 / —
▼
6. Complete Source Record Complete Source Record
The following content comes directly from the SASBDB entry. Missing values are shown as “—”; SAXSdb does not infer undeclared units.
Minimum q reliable is ~0.15 nm-1, approximated by a standard sample (lysozyme protein) scattering. DrugBank ID: DB11914: https://go.drugbank.com/drugs/DB11914
experiment_description
Synchrotron SAXS data from solutions of Immunoglobulin G4 in 10 mM sodium phosphate, pH 7 were collected on the BL-10C beam line at the Photon Factory High Energy Accelerator Research Organization (KEK; Tsukuba, Japan) using a Pilatus3 2M detector at a sample-detector distance of 1 m and at a wavelength of λ = 0.15 nm (I(s) vs s, where s = 4πsinθ/λ, and 2θ is the scattering angle). One solute concentration of 1.20 mg/ml was measured at 25°C. Five successive 2 second frames were collected. The data were normalized to the intensity of the transmitted beam and radially averaged; the scattering of the solvent-blank was subtracted.