2. Measurements Reported by SASBDB Reported Results
Metric
Method
Value
Uncertainty
Unit
dmax
P(r)
15.27
—
nm
i0
Guinier
0.540714
—
arbitrary
i0
P(r)
0.1807
—
arbitrary
mw
Experimental
55.6
—
kDa
mw
Porod
45.0
—
kDa
porod_volume
Porod
99.4
—
nm³
rg
Guinier
3.27
0.07
nm
rg
P(r)
3.365
—
nm
These values are reported by SASBDB; SAXSdb did not recalculate them from the experimental curve.
▼
3. Source Fits and Models Source Fits & Models
This entry has no source fit record.
▶
4. Source File Index Source Files
Category
Path
Download status
Size
curve
sasbdb/entries/h4/sasdwh4/source/SASDWH4.dat
downloaded
120393
full_entry_zip
sasbdb/entries/h4/sasdwh4/source/SASDWH4.zip
downloaded
54572
pddf
sasbdb/entries/h4/sasdwh4/source/SASDWH4.out
downloaded
77401
sascif
sasbdb/entries/h4/sasdwh4/source/SASDWH4.sascif
not_available
—
summary
sasbdb/entries/h4/sasdwh4/source/summary.json
downloaded
6054
▶
5. Experiment Description and Publication Experiment & Publication
Original Experiment Description
Synchrotron SAXS data from solutions of Class V GTP aptamer in 50 mM Bis-Tris, 50 mM KCl, 2 mM MgCl2, pH 6.5 were collected on the EMBL P12 beam line at PETRA III (DESY; Hamburg, Germany) using a Pilatus 6M detector at a sample-detector distance of 3 m and at a wavelength of λ = 0.123985 nm (I(s) vs s, where s = 4πsinθ/λ, and 2θ is the scattering angle). One solute concentration of 3.00 mg/ml was measured at 20°C. 40 successive 0.095 second frames were collected. The data were normalized to the intensity of the transmitted beam and radially averaged; the scattering of the solvent-blank was subtracted.
Related Publication
Title
Crystal structure of the class V GTP-binding RNA aptamer bound to its ligand: GTP recognition by a topologically complex intermolecular G-quadruplex.
Synchrotron SAXS data from solutions of Class V GTP aptamer in 50 mM Bis-Tris, 50 mM KCl, 2 mM MgCl2, pH 6.5 were collected on the EMBL P12 beam line at PETRA III (DESY; Hamburg, Germany) using a Pilatus 6M detector at a sample-detector distance of 3 m and at a wavelength of λ = 0.123985 nm (I(s) vs s, where s = 4πsinθ/λ, and 2θ is the scattering angle). One solute concentration of 3.00 mg/ml was measured at 20°C. 40 successive 0.095 second frames were collected. The data were normalized to the intensity of the transmitted beam and radially averaged; the scattering of the solvent-blank was subtracted.