2. Measurements Reported by SASBDB Reported Results
Metric
Method
Value
Uncertainty
Unit
dmax
P(r)
11.0
—
Å
i0
Guinier
42.5465
—
arbitrary
i0
P(r)
43.76
—
arbitrary
mw
Experimental
16125.0
—
kDa
mw
Porod
20.0
—
kDa
porod_volume
Porod
33.0
—
ų
rg
Guinier
2.432
0.071
Å
rg
P(r)
2.67
—
Å
These values are reported by SASBDB; SAXSdb did not recalculate them from the experimental curve.
▼
3. Source Fits and Models Source Fits & Models
This entry has no source fit record.
▶
4. Source File Index Source Files
Category
Path
Download status
Size
curve
sasbdb/entries/u8/sasdxu8/source/SASDXU8.dat
downloaded
36934
full_entry_zip
sasbdb/entries/u8/sasdxu8/source/SASDXU8.zip
downloaded
30903
pddf
sasbdb/entries/u8/sasdxu8/source/SASDXU8.out
downloaded
69476
sascif
sasbdb/entries/u8/sasdxu8/source/SASDXU8.sascif
not_available
—
summary
sasbdb/entries/u8/sasdxu8/source/summary.json
downloaded
8018
▶
5. Experiment Description and Publication Experiment & Publication
Original Experiment Description
Synchrotron SAXS data from solutions of Disordered repeats-in-toxin domain Block V of Bifunctional hemolysin/adenylate cyclase in 50 mM Tris, 5 mM DTT, pH 7.5 were collected on the BL4-2 beam line at the Stanford Synchrotron Radiation Lightsource (SSRL) storage ring (Menlo Park, CA, USA) using a Pilatus3 X 1M detector at a sample-detector distance of 1.7 m and at a wavelength of λ = 0.1127 nm (I(s) vs s, where s = 4πsinθ/λ, and 2θ is the scattering angle). One solute concentration of 10.00 mg/ml was measured at 21.9°C. 500 frames were collected with an exposure time of 2 seconds. The data were normalized to the intensity of the transmitted beam and radially averaged; the scattering of the solvent blank was subtracted.
Related Publication
Title
Ion-selective conformational stabilization of a disordered repeats-in-toxin protein domain.
Authors
Gudinas AP, Shambharkar GM, Chang MP, Fernández D, Matsui T, Mai DJ
DOI / PMID
10.1016/j.bpj.2025.10.014 / 41088755
▼
6. Complete Source Record Complete Source Record
The following content comes directly from the SASBDB entry. Missing values are shown as “—”; SAXSdb does not infer undeclared units.
Synchrotron SAXS data from solutions of Disordered repeats-in-toxin domain Block V of Bifunctional hemolysin/adenylate cyclase in 50 mM Tris, 5 mM DTT, pH 7.5 were collected on the BL4-2 beam line at the Stanford Synchrotron Radiation Lightsource (SSRL) storage ring (Menlo Park, CA, USA) using a Pilatus3 X 1M detector at a sample-detector distance of 1.7 m and at a wavelength of λ = 0.1127 nm (I(s) vs s, where s = 4πsinθ/λ, and 2θ is the scattering angle). One solute concentration of 10.00 mg/ml was measured at 21.9°C. 500 frames were collected with an exposure time of 2 seconds. The data were normalized to the intensity of the transmitted beam and radially averaged; the scattering of the solvent blank was subtracted.