X-ray synchrotron radiation scattering data from solutions of human cardiac myosin binding protein-C, domains C5-C6-C7 in 25 mM TrisHCl 250 mM NaCl, 2 mM TCEP, 0.02% sodium azide were collected on the SAXS/WAXS beam line of the Australian Synchrotron (Melbourne, Australia) using a Pilatus 1M-W pixel detector (I(s) vs s; s = 4π sin θ/λ, where 2θ is the scattering angle and λ=0.10332 nm). Different solute concentrations in the range 0.70-3.40 mg/ml were measured using a total exposure time of 44 s (recorded as 44 x 1 s frames). The data were normalized to the intensity of the transmitted beam and radially averaged and the scattering from the matched solvent-blank was subtracted. The data presented here represent the SAXS profile extrapolated to zero concentration calculated from the solute concentration series.
相关论文
Title
Clinically Linked Mutations in the Central Domains of Cardiac Myosin-Binding Protein C with Distinct Phenotypes Show Differential Structural Effects.
作者
Nadvi NA, Michie KA, Kwan AH, Guss JM, Trewhella J
School of Molecular Bioscience, University of Sydney.
experiment.contributor[0].affiliation[0].webpage
experiment.contributor[0].contributor_name
Jill
experiment.contributor[0].contributor_surname
Trewhella
experiment.contributor[0].orcid
null
experiment.concentration_method
null
experiment.concentration_unit
mg/ml
experiment.date
2015-04-18
experiment.storage_temperature
22.0
experiment.cell_temperature
22.0
experiment.exposure_time
1.0
experiment.number_of_frames
44
experiment.wavelength
null
experiment.sample_detector_distance
1.6
experiment.concentration_min
0.7
experiment.concentration_max
3.4
experiment.sample_volume
null
experiment.flow_rate
null
experiment.s_min
0.057
experiment.s_max
3.436
experiment.total_exposure_time
null
experiment.seccolumn
null
fits
[]
estimated_volume_method
null
pddf_software
ATSAS GNOM
pddf_software_version
null
i0_calibration_standard
null
description
null
experiment_description
X-ray synchrotron radiation scattering data from solutions of human cardiac myosin binding protein-C, domains C5-C6-C7 in 25 mM TrisHCl 250 mM NaCl, 2 mM TCEP, 0.02% sodium azide were collected on the SAXS/WAXS beam line of the Australian Synchrotron (Melbourne, Australia) using a Pilatus 1M-W pixel detector (I(s) vs s; s = 4π sin θ/λ, where 2θ is the scattering angle and λ=0.10332 nm). Different solute concentrations in the range 0.70-3.40 mg/ml were measured using a total exposure time of 44 s (recorded as 44 x 1 s frames). The data were normalized to the intensity of the transmitted beam and radially averaged and the scattering from the matched solvent-blank was subtracted. The data presented here represent the SAXS profile extrapolated to zero concentration calculated from the solute concentration series.