2. Measurements Reported by SASBDB Reported Results
Metric
Method
Value
Uncertainty
Unit
i0
Guinier
1198940.0
2464.0
arbitrary
mw
Experimental
8.0
—
kDa
rg
Guinier
1.34
0.07
nm
These values are reported by SASBDB; SAXSdb did not recalculate them from the experimental curve.
▼
3. Source Fits and Models Source Fits & Models
This entry has no source fit record.
▶
4. Source File Index Source Files
Category
Path
Download status
Size
curve
sasbdb/entries/s8/sasdcs8/source/SASDCS8.dat
downloaded
110629
full_entry_zip
sasbdb/entries/s8/sasdcs8/source/SASDCS8.zip
downloaded
31073
pddf
sasbdb/entries/s8/sasdcs8/source/SASDCS8.out
not_listed
—
sascif
sasbdb/entries/s8/sasdcs8/source/SASDCS8.sascif
downloaded
132342
summary
sasbdb/entries/s8/sasdcs8/source/summary.json
downloaded
5632
▶
5. Experiment Description and Publication Experiment & Publication
Original Experiment Description
Synchrotron SAXS data from solutions of cytochrome C in 50 mM Tris, pH 7.4 were collected at the EMBL-P12 beam line at the PETRA III storage ring (Hamburg, Germany) using an Eiger 4M detector at a sample-detector distance of 1.6 m and at a wavelength of λ = 0.124 nm (I(s) vs s, where s = 4πsinθ/λ and 2θ is the scattering angle). One solute concentration of 2.00 mg/ml was measured at 20°C. A single 1.3 millisecond frame was collected. The data were normalized to the intensity of the transmitted beam and radially averaged; the scattering of the solvent-blank was subtracted and the data were scaled to the protein concentration.
▼
6. Complete Source Record Complete Source Record
The following content comes directly from the SASBDB entry. Missing values are shown as “—”; SAXSdb does not infer undeclared units.
European Molecular Biology Laboratory (EMBL) - Hamburg outstation
experiment.contributor[0].affiliation[0].webpage
http://www.embl-hamburg.de/index.php
experiment.contributor[0].contributor_name
Clement
experiment.contributor[0].contributor_surname
Blanchet
experiment.contributor[0].orcid
null
experiment.concentration_method
null
experiment.concentration_unit
null
experiment.date
2016-12-21
experiment.storage_temperature
20.0
experiment.cell_temperature
20.0
experiment.exposure_time
0.001
experiment.number_of_frames
1
experiment.wavelength
0.124
experiment.sample_detector_distance
1.6
experiment.concentration_min
null
experiment.concentration_max
2.0
experiment.sample_volume
null
experiment.flow_rate
null
experiment.s_min
0.035
experiment.s_max
5.57
experiment.total_exposure_time
null
experiment.seccolumn
null
fits
[]
estimated_volume_method
null
pddf_software
null
pddf_software_version
null
i0_calibration_standard
null
description
null
experiment_description
Synchrotron SAXS data from solutions of cytochrome C in 50 mM Tris, pH 7.4 were collected at the EMBL-P12 beam line at the PETRA III storage ring (Hamburg, Germany) using an Eiger 4M detector at a sample-detector distance of 1.6 m and at a wavelength of λ = 0.124 nm (I(s) vs s, where s = 4πsinθ/λ and 2θ is the scattering angle). One solute concentration of 2.00 mg/ml was measured at 20°C. A single 1.3 millisecond frame was collected. The data were normalized to the intensity of the transmitted beam and radially averaged; the scattering of the solvent-blank was subtracted and the data were scaled to the protein concentration.