2. Measurements Reported by SASBDB Reported Results
Metric
Method
Value
Uncertainty
Unit
dmax
P(r)
19.5
—
Å
i0
Guinier
0.25
0.00034
arbitrary
i0
P(r)
0.2511
—
arbitrary
mw
Experimental
129.0
—
kDa
porod_volume
Porod
410.0
—
ų
rg
Guinier
5.681
0.059
Å
rg
P(r)
5.85
—
Å
These values are reported by SASBDB; SAXSdb did not recalculate them from the experimental curve.
▼
3. Source Fits and Models Source Fits & Models
This entry has no source fit record.
▶
4. Source File Index Source Files
Category
Path
Download status
Size
curve
sasbdb/entries/98/sasdd98/source/SASDD98.dat
downloaded
67352
full_entry_zip
sasbdb/entries/98/sasdd98/source/SASDD98.zip
downloaded
30772
pddf
sasbdb/entries/98/sasdd98/source/SASDD98.out
downloaded
32658
sascif
sasbdb/entries/98/sasdd98/source/SASDD98.sascif
downloaded
117826
summary
sasbdb/entries/98/sasdd98/source/summary.json
downloaded
6346
▶
5. Experiment Description and Publication Experiment & Publication
Original Experiment Description
Synchrotron SAXS data from solutions of human apolipoprotein E3 in 20 mM HEPES, 300 mM NaCl, pH 8 were collected on the B21 beam line at the Diamond Light Source (Oxfordshire, UK) using a Pilatus 2M detector at a sample-detector distance of 3.9 m and at a wavelength of λ = 0.1 nm (l(s) vs s, where s = 4πsinθ/λ, and 2θ is the scattering angle). One 3 second frame was collected at a sample temperature of 20°C. The data were normalized to the intensity of the transmitted beam and radially averaged; the scattering of the solvent-blank was subtracted.
Related Publication
Title
The molecular basis for Apolipoprotein E4 as the major risk factor for late onset Alzheimer's disease.
Authors
Raulin AC, Kraft L, Al-Hilaly YK, Xue WF, McGeehan JE, Atack JR, Serpell L
DOI / PMID
10.1016/j.jmb.2019.04.019 / 31051176
▼
6. Complete Source Record Complete Source Record
The following content comes directly from the SASBDB entry. Missing values are shown as “—”; SAXSdb does not infer undeclared units.
Synchrotron SAXS data from solutions of human apolipoprotein E3 in 20 mM HEPES, 300 mM NaCl, pH 8 were collected on the B21 beam line at the Diamond Light Source (Oxfordshire, UK) using a Pilatus 2M detector at a sample-detector distance of 3.9 m and at a wavelength of λ = 0.1 nm (l(s) vs s, where s = 4πsinθ/λ, and 2θ is the scattering angle). One 3 second frame was collected at a sample temperature of 20°C. The data were normalized to the intensity of the transmitted beam and radially averaged; the scattering of the solvent-blank was subtracted.