Procollagen lysyl hydroxylase LH3 measured using SEC-SAXS
Data type: SASBDB experimental dataStatus: PublishedCurve type: SEC-SASLast updated: 2019-12-06T13:07:15.624532+01:00
The sample was injected at a load concentration of 3.5 mg/mL. The SEC column used was a Superdex 200 PC 3.2/300 Increase (GE Healthcare) at a flow rate 0.075 mL/min.
▼
1. Samples, Components and Experimental Conditions Sample & Experiment
Sample 1 · Procollagen lysyl hydroxylase LH3 measured using SEC-SAXS
5. Experiment Description and Publication Experiment & Publication
Original Experiment Description
Synchrotron SAXS data from solutions of procollagen lysyl hydroxylase LH3 in 25 mM HEPES, 200 mM NaCl, pH 8 were measured at 20°C using SEC-SAXS collected on the BM29 beam line at the ESRF storage ring (Grenoble, France) equipped with a Pilatus 1M detector at a sample-detector distance of 2.9 m and at a wavelength of λ = 0.09919 nm (l(s) vs s, where s = 4πsinθ/λ, and 2θ is the scattering angle). One solute concentration of 3.50 mg/ml was injected onto the column. 75 successive 1 second frames were collected through the sample elution peak and processed using CHROMIXS that included the identification and subtraction of an appropriate solvent-blank.
Related Publication
Title
Molecular architecture of the multifunctional collagen lysyl hydroxylase and glycosyltransferase LH3.
Authors
Scietti L, Chiapparino A, De Giorgi F, Fumagalli M, Khoriauli L, Nergadze S, Basu S, Olieric V, Cucca L, Banushi B, Profumo A, Giulotto E, Gissen P, Forneris F
DOI / PMID
10.1038/s41467-018-05631-5 / 30089812
▼
6. Complete Source Record Complete Source Record
The following content comes directly from the SASBDB entry. Missing values are shown as “—”; SAXSdb does not infer undeclared units.
Every source field is expanded here, including empty values, list members and fields already shown above.
summary.json:156 field values
Field path
Raw value
code
SASDDW4
status
Published
type_of_curve
SEC-SAS
angular_unit
1/nm
project.title
Molecular architecture of the multifunctional collagen lysyl hydroxylase and glycosyltransferase LH3.
project.publication.title
Molecular architecture of the multifunctional collagen lysyl hydroxylase and glycosyltransferase LH3.
project.publication.author_list
Scietti L, Chiapparino A, De Giorgi F, Fumagalli M, Khoriauli L, Nergadze S, Basu S, Olieric V, Cucca L, Banushi B, Profumo A, Giulotto E, Gissen P, Forneris F
The sample was injected at a load concentration of 3.5 mg/mL. The SEC column used was a Superdex 200 PC 3.2/300 Increase (GE Healthcare) at a flow rate 0.075 mL/min.
experiment_description
Synchrotron SAXS data from solutions of procollagen lysyl hydroxylase LH3 in 25 mM HEPES, 200 mM NaCl, pH 8 were measured at 20°C using SEC-SAXS collected on the BM29 beam line at the ESRF storage ring (Grenoble, France) equipped with a Pilatus 1M detector at a sample-detector distance of 2.9 m and at a wavelength of λ = 0.09919 nm (l(s) vs s, where s = 4πsinθ/λ, and 2θ is the scattering angle). One solute concentration of 3.50 mg/ml was injected onto the column. 75 successive 1 second frames were collected through the sample elution peak and processed using CHROMIXS that included the identification and subtraction of an appropriate solvent-blank.