2. Measurements Reported by SASBDB Reported Results
Metric
Method
Value
Uncertainty
Unit
dmax
P(r)
18.26
—
Å
i0
Guinier
0.0189
6.4e-05
arbitrary
i0
P(r)
0.01877
—
arbitrary
mw
Experimental
298.0
—
kDa
mw
Porod
317.0
—
kDa
porod_volume
Porod
508.0
—
ų
rg
Guinier
5.179
0.03
Å
rg
P(r)
5.12
—
Å
These values are reported by SASBDB; SAXSdb did not recalculate them from the experimental curve.
▼
3. Source Fits and Models Source Fits & Models
This entry has no source fit record.
▶
4. Source File Index Source Files
Category
Path
Download status
Size
curve
sasbdb/entries/92/sasde92/source/SASDE92.dat
downloaded
83973
full_entry_zip
sasbdb/entries/92/sasde92/source/SASDE92.zip
downloaded
38573
pddf
sasbdb/entries/92/sasde92/source/SASDE92.out
downloaded
57983
sascif
sasbdb/entries/92/sasde92/source/SASDE92.sascif
downloaded
141457
summary
sasbdb/entries/92/sasde92/source/summary.json
downloaded
7658
▶
5. Experiment Description and Publication Experiment & Publication
Original Experiment Description
Synchrotron SAXS data from solutions of Ribonuclease E from Acinetobacter baumannii in 10 mM DTT, 10 mM MgCl2, 0.5 M NaCl, 20 mM Tris, pH 8 were collected on the B21 beam line at the Diamond Light Source (Oxfordshire, UK) using a Pilatus 2M detector at a sample-detector distance of 4.0 m and at a wavelength of λ = 0.1 nm (l(s) vs s, where s = 4πsinθ/λ, and 2θ is the scattering angle). One solute concentration of 5.52 mg/ml was measured at 15°C. 640 successive 3 second frames were collected. The data were normalized to the intensity of the transmitted beam and radially averaged; the scattering of the solvent-blank was subtracted.
Related Publication
Title
A structural and biochemical comparison of Ribonuclease E homologues from pathogenic bacteria highlights species-specific properties.
Authors
Mardle CE, Shakespeare TJ, Butt LE, Goddard LR, Gowers DM, Atkins HS, Vincent HA, Callaghan AJ
DOI / PMID
10.1038/s41598-019-44385-y / 31138855
▼
6. Complete Source Record Complete Source Record
The following content comes directly from the SASBDB entry. Missing values are shown as “—”; SAXSdb does not infer undeclared units.
Synchrotron SAXS data from solutions of Ribonuclease E from Acinetobacter baumannii in 10 mM DTT, 10 mM MgCl2, 0.5 M NaCl, 20 mM Tris, pH 8 were collected on the B21 beam line at the Diamond Light Source (Oxfordshire, UK) using a Pilatus 2M detector at a sample-detector distance of 4.0 m and at a wavelength of λ = 0.1 nm (l(s) vs s, where s = 4πsinθ/λ, and 2θ is the scattering angle). One solute concentration of 5.52 mg/ml was measured at 15°C. 640 successive 3 second frames were collected. The data were normalized to the intensity of the transmitted beam and radially averaged; the scattering of the solvent-blank was subtracted.