Synchrotron SAXS data from solutions of SARS-CoV-2 N-protein (amino acids 1-245) in 100 mM Tris-HCl, 150 mM NaCl, 1 mM EDTA, pH 8 were collected on the B21 beam line at the Diamond Light Source (Didcot, UK) using a Eiger 4M detector at a sample-detector distance of 3.7 m and at a wavelength of λ = 0.0954 nm (I(s) vs s, where s = 4πsinθ/λ, and 2θ is the scattering angle). One solute concentration of 4.60 mg/ml was measured at 10°C. 10 successive 2 second frames were collected. The data were normalized to the intensity of the transmitted beam and radially averaged; the scattering of the solvent-blank was subtracted.
相关论文
标题
Dynamic ensembles of SARS-CoV-2 N-protein reveal head-to-head coiled-coil-driven oligomerization and phase separation.
Strep(II)-tagged N-protein 1-245. The protein construct used for SAXS contains an additional two amino acids at the N-terminus (GP) as well as the VWSHPQFEK C-terminal tag.
Instituto de Tecnologia Química e Biológica António Xavier, Universidade de Lisboa
experiment.contributor[0].affiliation[0].webpage
http://www.itqb.unl.pt
experiment.contributor[0].contributor_name
Guillem
experiment.contributor[0].contributor_surname
Hernandez
experiment.contributor[0].orcid
https://orcid.org/0000-0003-4438-5611
experiment.concentration_method
null
experiment.concentration_unit
null
experiment.date
2022-05-13
experiment.storage_temperature
10.0
experiment.cell_temperature
10.0
experiment.exposure_time
2.0
experiment.number_of_frames
10
experiment.wavelength
0.0954
experiment.sample_detector_distance
3.69
experiment.concentration_min
null
experiment.concentration_max
4.6
experiment.sample_volume
null
experiment.flow_rate
null
experiment.s_min
0.045
experiment.s_max
3.4
experiment.total_exposure_time
null
experiment.seccolumn
null
fits
[]
estimated_volume_method
null
pddf_software
ATSAS GNOM
pddf_software_version
5.0
i0_calibration_standard
null
description
null
experiment_description
Synchrotron SAXS data from solutions of SARS-CoV-2 N-protein (amino acids 1-245) in 100 mM Tris-HCl, 150 mM NaCl, 1 mM EDTA, pH 8 were collected on the B21 beam line at the Diamond Light Source (Didcot, UK) using a Eiger 4M detector at a sample-detector distance of 3.7 m and at a wavelength of λ = 0.0954 nm (I(s) vs s, where s = 4πsinθ/λ, and 2θ is the scattering angle). One solute concentration of 4.60 mg/ml was measured at 10°C. 10 successive 2 second frames were collected. The data were normalized to the intensity of the transmitted beam and radially averaged; the scattering of the solvent-blank was subtracted.