5. Experiment Description and Publication Experiment & Publication
Original Experiment Description
Synchrotron SAXS data from solutions of TET12(1.6)S-c6b in 20 mM Tris 150 mM NaCl 10% glycerol, pH 7.5 were collected on the P12 beam line at the PETRA III storage ring (Hamburg, Germany) using a Pilatus 1M detector at a sample-detector distance of 2 m and at a wavelength of λ = 0.124 nm (I(s) vs s, where s = 4πsinθ/λ and 2θ is the scattering angle). Solute concentrations ranging between 1 and 5 mg/ml were measured at 20°C. 20 successive 0.045 second frames were collected. The data were normalized to the intensity of the transmitted beam and radially averaged; the scattering of the solvent-blank was subtracted and the different curves were scaled for protein concentration. Scattering curves were merged and analyzed using PRIMUS software.
Related Publication
Title
Design of coiled-coil protein-origami cages that self-assemble in vitro and in vivo.
Authors
Ljubetič A, Lapenta F, Gradišar H, Drobnak I, Aupič J, Strmšek Ž, Lainšček D, Hafner-Bratkovič I, Majerle A, Krivec N, Benčina M, Pisanski T, Veličković TĆ, Round A, Carazo JM, Melero R, Jerala R
DOI / PMID
10.1038/nbt.3994 / 29035374
▼
6. Complete Source Record Complete Source Record
The following content comes directly from the SASBDB entry. Missing values are shown as “—”; SAXSdb does not infer undeclared units.
Every source field is expanded here, including empty values, list members and fields already shown above.
summary.json:156 field values
Field path
Raw value
code
SASDCZ7
status
Published
type_of_curve
Merged
angular_unit
1/nm
project.title
Design of coiled-coil protein-origami cages that self-assemble in vitro and in vivo.
project.publication.title
Design of coiled-coil protein-origami cages that self-assemble in vitro and in vivo.
project.publication.author_list
Ljubetič A, Lapenta F, Gradišar H, Drobnak I, Aupič J, Strmšek Ž, Lainšček D, Hafner-Bratkovič I, Majerle A, Krivec N, Benčina M, Pisanski T, Veličković TĆ, Round A, Carazo JM, Melero R, Jerala R
Synchrotron SAXS data from solutions of TET12(1.6)S-c6b in 20 mM Tris 150 mM NaCl 10% glycerol, pH 7.5 were collected on the P12 beam line at the PETRA III storage ring (Hamburg, Germany) using a Pilatus 1M detector at a sample-detector distance of 2 m and at a wavelength of λ = 0.124 nm (I(s) vs s, where s = 4πsinθ/λ and 2θ is the scattering angle). Solute concentrations ranging between 1 and 5 mg/ml were measured at 20°C. 20 successive 0.045 second frames were collected. The data were normalized to the intensity of the transmitted beam and radially averaged; the scattering of the solvent-blank was subtracted and the different curves were scaled for protein concentration. Scattering curves were merged and analyzed using PRIMUS software.